Ysly kudhibiti cable multicore cable cable pvc cable data viwanda mawasiliano kudhibiti cable cable cable
Ujenzi wa cable
1. Conductor: Conductor wa shaba, laini laini iliyopigwa, Darasa la 5, Acc. kwa IEC 60228 / HD 383 / DIN VDE 0295
2. Insulation: PVC kiwanja Ti2 Acc. kwa HD 21.1 / DIN VDE 0281 au YI2 ACC. kwa VDE 0207.4
• Na msingi wa kijani-kijani, kila wakati kwenye safu ya nje (cores ≥3) au bila msingi wa kijani-kijani-njano)
• Kuweka alama ya msingi: (acc. To din vde 0293) Nyeusi imehesabiwa
• Cores zilizowekwa kwenye tabaka
3. Sheath: kiwanja cha PVC TM2 ACC. kwa HD 21.1 / DIN VDE 0281 au YM2 ACC, kwa VDE 0207.5A
• Rangi ya Sheath: Grey (RAL 7001)
Takwimu za kiufundi
Mbio za joto:
• Wakati wa ufungaji na matumizi na kupiga: -5 ° C hadi +50 ° C
• Zisizohamishika zilizowekwa: -30 ° C hadi +70 ° C.
Voltage ya kawaida: U0 /U = 300/500 V.
Voltage ya mtihani: min. 4000 V.
Upinzani wa insulation: min. 20 MΩ x km
Radi ndogo ya kuinama: (d = cablenjekipenyo)
• Zisizohamishika zilizowekwa: 4d
• Katika matumizi na kuinama: 15d
Tabia ya Moto: Moto Retardant IEC/ EN 60332-1
Maombi
Cable ya kudhibiti rahisi inayotumika kwa kuashiria na udhibiti wa vifaa vya tuli au vya rununu katika tasnia, mimea ya umeme au ofisi.
Nyepesi na nyembamba, sugu kwa mizigo ya kati ya mitambo, inayotumiwa kwa mitambo ya simu ya kudumu au ndogo (sio ya simu ya kudumu) bila mzigo mgumu. Imewekwa katika majengo kavu au ya unyevu, matumizi ya nje tu chini ya ulinzi dhidi ya UV-irradiation. Haikusudiwa kuwekewa ardhini au maji.
Ujenzi wa conductor na upinzani
Conductor sehemu ya msalabaeneo | No ya waya x kipenyo | Unene wa insulation | Upinzani wa conductor saa 20 ℃max. |
mm2 | N x mm | mm | Ω/km |
0.5 | 16 x 0.20 | 0.4 | 39.0 |
0.75 | 24 x 0.20 | 0.4 | 26.0 |
1 | 32 x 0.20 | 0.4 | 19.5 |
1.5 | 30 x 0.25 | 0.5 | 13.3 |
2.5 | 50 x 0.25 | 0.7 | 7.98 |
4 | 56 x 0.30 | 0.8 | 4.95 |
6 | 84 x 0.30 | 0.8 | 3.3 |
10 | 80 x 0.40 | 1 | 1.91 |
16 | 128 x 0.40 | 1 | 1.21 |
Vipimo vya cable
YSLY-JZ iliyohesabiwa na conductor kijani/manjano
Ysly-Oz alihesabu cores bila conductor kijani/manjano
Ujenzi | Nominalinsulation nenes | NominalSheath unene | Takriban. Kipenyo cha nje cha cable | Max. upinzani saa 20 ° C. | Takriban. cable uzani |
Coresx mm2 | mm | mm | mm | Ω/km | kilo/km |
2 x 0,5 | 0,4 | 0,7 | 4,4 | 39,0 | 30 |
3 x 0,5 | 0,4 | 0,7 | 4,7 | 39,0 | 35 |
4 x 0,5 | 0,4 | 0,7 | 5,1 | 39,0 | 43 |
5 x 0,5 | 0,4 | 0,7 | 5,5 | 39,0 | 52 |
6 x 0,5 | 0,4 | 0,8 | 6,2 | 39,0 | 64 |
7 x 0,5 | 0,4 | 0,8 | 6,2 | 39,0 | 67 |
10 x 0,5 | 0,4 | 0,9 | 7,4 | 39,0 | 93 |
12 x 0,5 | 0,4 | 0,9 | 7,9 | 39,0 | 108 |
14 x 0,5 | 0,4 | 1,0 | 8,7 | 39,0 | 127 |
16 x 0,5 | 0,4 | 1,0 | 9,2 | 39,0 | 144 |
18 x 0,5 | 0,4 | 1,0 | 9,7 | 39,0 | 160 |
21 x 0,5 | 0,4 | 1,1 | 10,4 | 39,0 | 190 |
25 x 0,5 | 0,4 | 1,2 | 11,1 | 39,0 | 215 |
27 x 0,5 | 0,4 | 1,2 | 11,8 | 39,0 | 233 |
34 x 0,5 | 0,4 | 1,3 | 12,9 | 39,0 | 287 |
40 x 0,5 | 0,4 | 1,3 | 14,2 | 39,0 | 345 |
42 x 0,5 | 0,4 | 1,4 | 14,6 | 39,0 | 360 |
52 x 0,5 | 0,4 | 1,5 | 16,0 | 39,0 | 430 |
61 x 0,5 | 0,4 | 1,6 | 17,1 | 39,0 | 501 |
YSLY-JZ iliyohesabiwa na conductor kijani/manjano
Ysly-Oz alihesabu cores bila conductor kijani/manjano
Ujenzi | Nominalinsulation nenes | NominalSheath unene | Takriban. Kipenyo cha nje cha cable | Max. upinzani saa 20 ° C. | Takriban. cable uzani |
Nx mm2 | mm | mm | mm | Ω/km | kilo/km |
2 x 0,75 | 0,4 | 0,7 | 4,8 | 26,0 | 37 |
3 x 0,75 | 0,4 | 0,7 | 5,1 | 26,0 | 45 |
4 x 0,75 | 0,4 | 0,7 | 5,5 | 26,0 | 54 |
5 x 0,75 | 0,4 | 0,8 | 6,2 | 26,0 | 69 |
6 x 0,75 | 0,4 | 0,8 | 6,8 | 26,0 | 82 |
7 x 0,75 | 0,4 | 0,8 | 6,8 | 26,0 | 86 |
10 x 0,75 | 0,4 | 1,0 | 8,3 | 26,0 | 124 |
12 x 0,75 | 0,4 | 1,0 | 8,9 | 26,0 | 144 |
14 x 0,75 | 0,4 | 1,0 | 9,6 | 26,0 | 165 |
16 x 0,75 | 0,4 | 1,1 | 10,3 | 26,0 | 192 |
18 x 0,75 | 0,4 | 1,1 | 10,9 | 26,0 | 213 |
21 x 0,75 | 0,4 | 1,2 | 11,6 | 26,0 | 243 |
25 x 0,75 | 0,4 | 1,3 | 12,4 | 26,0 | 287 |
YSLY-JZ iliyohesabiwa na conductor kijani/manjano
Ysly-Oz alihesabu cores bila conductor kijani/manjano
Ujenzi | Nominalinsulation nenes | NominalSheath unene | Takriban. Kipenyo cha nje cha cable | Max. upinzani saa 20 ° C. | Takriban. cable uzani |
Nx mm2 | mm | mm | mm | Ω/km | kilo/km |
2 x 1 | 0,4 | 0,7 | 5,1 | 19,5 | 44 |
3 x 1 | 0,4 | 0,7 | 5,4 | 19,5 | 54 |
4 x 1 | 0,4 | 0,8 | 6,1 | 19,5 | 69 |
5 x 1 | 0,4 | 0,8 | 6,6 | 19,5 | 84 |
6 x 1 | 0,4 | 0,9 | 7,4 | 19,5 | 103 |
7 x 1 | 0,4 | 0,9 | 7,4 | 19,5 | 109 |
10 x 1 | 0,4 | 1,0 | 8,9 | 19,5 | 152 |
12 x 1 | 0,4 | 1,0 | 9,5 | 19,5 | 177 |
14 x 1 | 0,4 | 1,1 | 10,5 | 19,5 | 208 |
16 x 1 | 0,4 | 1,1 | 11,0 | 19,5 | 235 |
18 x 1 | 0,4 | 1,2 | 11,8 | 19,5 | 263 |
21 x 1 | 0,4 | 1,2 | 12,4 | 19,5 | 297 |
25 x 1 | 0,4 | 1,3 | 13,2 | 19,5 | 354 |
YSLY-JZ iliyohesabiwa na conductor kijani/manjano
Ysly-Oz alihesabu cores bila conductor kijani/manjano
Ujenzi | Nominalinsulation nenes | NominalSheath unene | Takriban. Kipenyo cha nje cha cable | Max. upinzani saa 20 ° C. | Takriban. cable uzani |
Nx mm2 | mm | mm | mm | Ω/km | kilo/km |
2 x 1,5 | 0,4 | 0,8 | 5,8 | 13,3 | 59 |
3 x 1,5 | 0,4 | 0,8 | 6,1 | 13,3 | 73 |
4 x 1,5 | 0,4 | 0,8 | 6,7 | 13,3 | 90 |
5 x 1,5 | 0,4 | 0,9 | 7,5 | 13,3 | 113 |
6 x 1,5 | 0,4 | 0,9 | 8,2 | 13,3 | 134 |
7 x 1,5 | 0,4 | 0,9 | 8,2 | 13,3 | 144 |
10 x 1,5 | 0,4 | 1,1 | 10,0 | 13,3 | 205 |
12 x 1,5 | 0,4 | 1,1 | 10,7 | 13,3 | 239 |
14 x 1,5 | 0,4 | 1,2 | 11,8 | 13,3 | 281 |
16 x 1,5 | 0,4 | 1,2 | 12,4 | 13,3 | 318 |
18 x 1,5 | 0,4 | 1,3 | 13,3 | 13,3 | 361 |
21 x 1,5 | 0,4 | 1,3 | 14,0 | 13,3 | 423 |
25 x 1,5 | 0,4 | 1,5 | 15,1 | 13,3 | 489 |
YSLY-JZ iliyohesabiwa na conductor kijani/manjano
Ysly-Oz alihesabu cores bila conductor kijani/manjano
Ujenzi | Nominalinsulation nenes | NominalSheath unene | Takriban. Kipenyo cha nje cha cable | Max. upinzani saa 20 ° C. | Takriban. cable uzani |
Nx mm2 | mm | mm | mm | Ω/km | kilo/km |
2 x 2,5 | 0,5 | 0,8 | 7,1 | 7,98 | 91 |
3 x 2,5 | 0,5 | 0,9 | 7,8 | 7,98 | 117 |
4 x 2,5 | 0,5 | 0,9 | 8,5 | 7,98 | 144 |
5 x 2,5 | 0,5 | 1,0 | 9,5 | 7,98 | 183 |
7 x 2,5 | 0,5 | 1,1 | 10,5 | 7,98 | 237 |
12 x 2,5 | 0,5 | 1,3 | 13,7 | 7,98 | 393 |
18 x 2,5 | 0,5 | 1,5 | 16,9 | 7,98 | 592 |
2 x 4 | 0,5 | 0,9 | 8,3 | 4,95 | 131 |
3 x 4 | 0,5 | 1,0 | 9,0 | 4,95 | 170 |
4 x 4 | 0,5 | 1,0 | 9,9 | 4,95 | 212 |
5 x 4 | 0,5 | 1,1 | 11,0 | 4,95 | 267 |
7 x 4 | 0,5 | 1,2 | 12,2 | 4,95 | 349 |
3 x 6 | 0,6 | 1,1 | 10,9 | 3,30 | 249 |
4 x 6 | 0,6 | 1,2 | 12,1 | 3,30 | 317 |
5 x 6 | 0,6 | 1,3 | 13,4 | 3,30 | 399 |
7 x 6 | 0,6 | 1,4 | 14,9 | 3,30 | 518 |
YSLY-JZ iliyohesabiwa na conductor kijani/manjano
Ysly-Oz alihesabu cores bila conductor kijani/manjano
Ujenzi | Nominalinsulation nenes | NominalSheath unene | Takriban. Kipenyo cha nje cha cable | Max. upinzani saa 20 ° C. | Takriban. cable uzani |
Nx mm2 | mm | mm | mm | Ω/km | kilo/km |
3 x 10 | 0,7 | 1,3 | 13,7 | 1,91 | 428 |
4 x 10 | 0,7 | 1,4 | 15,2 | 1,91 | 539 |
5 x 10 | 0,7 | 1,5 | 17,0 | 1,91 | 672 |
7 x 10 | 0,7 | 1,6 | 18,7 | 1,91 | 877 |
4 x 16 | 0,7 | 1,5 | 17,9 | 1,21 | 791 |
5 x 16 | 0,7 | 1,7 | 20,0 | 1,21 | 990 |